To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use the gas detector before reading this manual.

1. Description

         KB8100 Gas Monitor System is a multipoint controller system. It is used for detecting gas concentration in the air. The system could connect to detectors for different gases in the same time. The system adopts MCU as control unit, excellent gas sensor with high sensitivity and fast response. It will give visual and audible alarm when the gas concentration reach or exceed the presetting alarm level to remind you to take effective actions in time and it could also start the ventilation fan and other equipment to prevent from accident and explosions.

 

2. Features and Specifications

2.1 Features

²  MCU with functions: data real time check, fault detecting, power management, alarm display, alarm indication, relay outputs etc;

²  8 simulate channels for 4-20mA detectors;

²  1 signal for RS-485 with capacity of 32pcs digital detectors;

²  Simulate channel and digital channel together. maximum detectors is 40;

²  Manage different gas detectors, different level and different digital unit detectors;

²  Intelligent system: easy zero calibration; free relay output;

²  8 passive relay contact output, linkage programmer;

2.2 Specifications

Installation method: wall-mounted

Detector model: BS01, BS03, and TC200.

Response time: 10s

Indication method:

Large LCD display real time data and system state

Visual and audio indication for alarm and fault

Contact output: passive contact   capacity 2A/AC220V

Working method: continuous work

Working temperature:  050

Working humidity: 95%RH

Main power: AC220V±15%

Backup power: 2pcs DC12V/7.5AH chargeable battery

Consumption: ≤10W

Detector power supplyDC24V±25%

Alarm value of backup battery: DC21V±1V

Overall size: 430mm×291mm×104mm

Connection of detector and panel: ≥RVVP 4×2.5 mm2

Distance: ≤1000m 

composing

The system consists of one control panel, detectors (40pcs in maximum), and controller (27pcs maximum)

Note: the total quantity of detector and controller is 40pcs.